Home Cognos Error Base CM-SYS-5170 Content manager is unable to clean deleted referenced objects
Follow us on Twitter
CM-SYS-5170 Content manager is unable to clean deleted referenced objects Print E-mail
(0 votes, average 0 out of 5)




Errorcode
CM-SYS-5170
Decription
Content Manager is unable to clean deleted referenced objects.
Component

CM

Content Manager

SubComponent
SYSSystem error messages
Solution
Symptom
In Cognos Connection:
CM-SYS-5170 Content manager is unable to clean deleted referenced objects
CM-SYS-5003 Content manager is unable to access the content store. Verify your database connection parameters and then contact your database administrator.
CM-CFG-5065 A content manager configuration error was detected while attempting to execute the content initialization script
DPR-CMI-4006 Unable to determine the active Content Manager. Will retry periodically
DPR-DPR-1035 Dispatcher detected an error

Problem
Unable to start the Cognos 8 Service

Cause
SQL Server was configured to allow only 3 concurrent connections to the instance where the Cognos databases were located.

Solution
Change the setting to allow unlimited concurrent connections to the instance.
Steps:
1. Open SQL Server Enterprise Manager
2. Right-mouse click on the SQL Server Registration (computer name) and click on Properties.
3. Access the Connections tab - Change the Maximum concurrent user connections to 0 for unlimited or a higher number to allow the required connections from Cognos 8.